Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Arq Bras Cardiol ; 110(4): 383-387, 2018 Apr.
Artigo em Português, Inglês | MEDLINE | ID: mdl-29791580

RESUMO

The study of myocardial contractility, based on the new anatomical concepts that govern cardiac mechanics, represents a promising strategy of analysis of myocardial adaptations related to physical training in the context of post-infarction. We investigated the influence of aerobic training on physical capacity and on the evaluation parameters of left ventricular contraction mechanics in patients with myocardial infarction. Thirty-one patients (55.1 ± 8.9 years) who had myocardial infarction in the anterior wall were prospectively investigated in three groups: interval training group (ITG) (n = 10), moderate training group (MTG) n = 10) and control group (CG) (n = 10). Before and after 12 weeks of clinical follow-up, patients underwent cardiopulmonary exercise testing and cardiac magnetic resonance imaging. The trained groups performed supervised aerobic training on treadmill, in two different intensities. A statistically significant increase in peak oxygen uptake (VO2) was observed in the ITG (19.2 ± 5.1 at 21.9 ± 5.6 ml/kg/min, p < 0.01) and in the MTG 18.8 ± 3.7 to 21.6 ± 4.5 ml/kg/min, p < 0.01). The GC did not present a statistically significant change in peak VO2. A statistically significant increase in radial strain (STRAD) was observed in the CG: basal STRAD (57.4 ± 16.6 to 84.1 ± 30.9%, p < 0.05), medial STRAD (57.8 ± 27, 9 to 74.3 ± 36.1%, p < 0.05) and apical STRAD (38.2 ± 26.0 to 52.4 ± 29.8%, p < 0.01). The trained groups did not present a statistically significant change of the radial strain. The present study points to a potential clinical application of the parameters of ventricular contraction mechanics analysis, especially radial strain, to discriminate post-infarction myocardial adaptations between patients submitted or not to aerobic training programs.


Assuntos
Terapia por Exercício/métodos , Exercício Físico/fisiologia , Contração Miocárdica/fisiologia , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/reabilitação , Função Ventricular Esquerda/fisiologia , Pressão Sanguínea/fisiologia , Teste de Esforço/métodos , Frequência Cardíaca/fisiologia , Ventrículos do Coração/fisiopatologia , Humanos , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento
2.
Arq. bras. cardiol ; 110(4): 383-387, Apr. 2018. tab
Artigo em Inglês | LILACS | ID: biblio-1038530

RESUMO

Abstract The study of myocardial contractility, based on the new anatomical concepts that govern cardiac mechanics, represents a promising strategy of analysis of myocardial adaptations related to physical training in the context of post-infarction. We investigated the influence of aerobic training on physical capacity and on the evaluation parameters of left ventricular contraction mechanics in patients with myocardial infarction. Thirty-one patients (55.1 ± 8.9 years) who had myocardial infarction in the anterior wall were prospectively investigated in three groups: interval training group (ITG) (n = 10), moderate training group (MTG) n = 10) and control group (CG) (n = 10). Before and after 12 weeks of clinical follow-up, patients underwent cardiopulmonary exercise testing and cardiac magnetic resonance imaging. The trained groups performed supervised aerobic training on treadmill, in two different intensities. A statistically significant increase in peak oxygen uptake (VO2) was observed in the ITG (19.2 ± 5.1 at 21.9 ± 5.6 ml/kg/min, p < 0.01) and in the MTG 18.8 ± 3.7 to 21.6 ± 4.5 ml/kg/min, p < 0.01). The GC did not present a statistically significant change in peak VO2. A statistically significant increase in radial strain (STRAD) was observed in the CG: basal STRAD (57.4 ± 16.6 to 84.1 ± 30.9%, p < 0.05), medial STRAD (57.8 ± 27, 9 to 74.3 ± 36.1%, p < 0.05) and apical STRAD (38.2 ± 26.0 to 52.4 ± 29.8%, p < 0.01). The trained groups did not present a statistically significant change of the radial strain. The present study points to a potential clinical application of the parameters of ventricular contraction mechanics analysis, especially radial strain, to discriminate post-infarction myocardial adaptations between patients submitted or not to aerobic training programs.


Resumo O estudo da contratilidade miocárdica, baseado nos novos conceitos anatômicos que regem a mecânica cardíaca, representa uma estratégia promissora de análise das adaptações do miocárdio relacionadas ao treinamento físico no contexto do pós-infarto. Nós investigamos a influência do treinamento aeróbico na capacidade física e nos parâmetros de avaliação da mecânica de contração do ventrículo esquerdo em pacientes com infarto do miocárdio. Foram prospectivamente investigados 30 pacientes, 55,1 ± 8,9 anos, acometidos por infarto do miocárdio de parede anterior, aleatorizados em três grupos: grupo treinamento intervalado (GTI) (n = 10), grupo treinamento moderado (GTM) (n=10) e grupo controle (GC) (n = 10). Antes e após as 12 semanas de seguimento clínico, os pacientes realizaram teste cardiopulmonar de exercício e ressonância magnética cardíaca. Os grupos treinados realizaram treinamento aeróbico supervisionado, em esteira ergométrica, aplicando-se duas intensidades distintas. Observou-se aumento estatisticamente significante do consumo de oxigênio (VO2) pico no GTI (19,2 ± 5,1 para 21,9 ± 5,6 ml/kg/min, p < 0,01) e no GTM (18,8 ± 3,7 para 21,6 ± 4,5 ml/kg/min, p < 0,01). O GC não apresentou mudança estatisticamente significante no VO2 pico. Houve aumento estatisticamente significante do strain radial (STRAD) somente no GC: STRAD basal (57,4 ± 16,6 para 84,1 ± 30,9%, p < 0,05), STRAD medial (57,8 ± 27,9 para 74,3 ± 36,1%, p < 0,05) e STRAD apical (38,2 ± 26,0 para 52,4 ± 29,8%, p < 0,01). Os grupos treinados não apresentaram mudança estatisticamente significante do strain radial. Os achados do presente estudo apontam para uma potencial aplicação clínica dos parâmetros de análise da mecânica de contração ventricular, notadamente do strain radial, em discriminar adaptações do miocárdio pós-infarto entre pacientes submetidos ou não a programas de treinamento aeróbico.


Assuntos
Humanos , Pessoa de Meia-Idade , Exercício Físico/fisiologia , Função Ventricular Esquerda/fisiologia , Terapia por Exercício/métodos , Contração Miocárdica/fisiologia , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/reabilitação , Consumo de Oxigênio/fisiologia , Fatores de Tempo , Pressão Sanguínea/fisiologia , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento , Estatísticas não Paramétricas , Teste de Esforço/métodos , Frequência Cardíaca/fisiologia , Ventrículos do Coração/fisiopatologia
3.
Asian Pac J Cancer Prev ; 18(5): 1371-1376, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28612588

RESUMO

Introduction: Human papillomavirus (HPV), belonging to the Papovavirida family, is the most prevalent sexually transmitted disease (STD) agent worldwide. In Brazil, it is estimated that there are 3-6 million people infected with HPV. Aim: The aim of this study was to evaluate the knowledge of young male students about penis cancer related to HPV infection. Methods: This exploratory and quantitative study was conducted to analyze answers of 242 male students attending a private college located in Uberaba city, Minas Gerais state, Brazil, during 2015. Results: Most of the 242 participants (88.8%) affirmed having started sexual life very early, the majority (79.3%) were currently married and 69.8% had a single sexual partner. Regardless of their knowledge about HPV virus and its relationship with penis cancer, our data showed a general lack of awareness of the participants. Conclusion: Our results suggest that despite efforts to propagate information about HPV infection and its relation to penis cancer, the level of knowledge of students is low. Because of that, it is important to improve the information spread by media, emphasizing prevention and treatment of HPV infection in men.

4.
Arq Bras Cardiol ; 108(1): 12-20, 2017 Jan.
Artigo em Português, Inglês | MEDLINE | ID: mdl-28146205

RESUMO

BACKGROUND: Radionuclide ventriculography (RV) is a validated method to evaluate the left ventricular systolic function (LVSF) in small rodents. However, no prior study has compared the results of RV with those obtained by other imaging methods in this context. OBJECTIVES: To compare the results of LVSF obtained by RV and echocardiography (ECHO) in an experimental model of cardiotoxicity due to doxorubicin (DXR) in rats. METHODS: Adult male Wistar rats serving as controls (n = 7) or receiving DXR (n = 22) in accumulated doses of 8, 12, and 16 mg/kg were evaluated with ECHO performed with a Sonos 5500 Philips equipment (12-MHz transducer) and RV obtained with an Orbiter-Siemens gamma camera using a pinhole collimator with a 4-mm aperture. Histopathological quantification of myocardial fibrosis was performed after euthanasia. RESULTS: The control animals showed comparable results in the LVSF analysis obtained with ECHO and RV (83.5 ± 5% and 82.8 ± 2.8%, respectively, p > 0.05). The animals that received DXR presented lower LVSF values when compared with controls (p < 0.05); however, the LVSF values obtained by RV (60.6 ± 12.5%) were lower than those obtained by ECHO (71.8 ± 10.1%, p = 0.0004) in this group. An analysis of the correlation between the LVSF and myocardial fibrosis showed a moderate correlation when the LVSF was assessed by ECHO (r = -0.69, p = 0.0002) and a stronger correlation when it was assessed by RV (r = -0.79, p < 0.0001). On multiple regression analysis, only RV correlated independently with myocardial fibrosis. CONCLUSION: RV is an alternative method to assess the left ventricular function in small rodents in vivo. When compared with ECHO, RV showed a better correlation with the degree of myocardial injury in a model of DXR-induced cardiotoxicity.


Assuntos
Ecocardiografia , Ventriculografia com Radionuclídeos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Animais , Antibióticos Antineoplásicos , Cardiotoxicidade/diagnóstico por imagem , Modelos Animais de Doenças , Doxorrubicina , Fibrose , Masculino , Ratos Wistar , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/patologia , Função Ventricular Esquerda/efeitos dos fármacos
5.
Arq. bras. cardiol ; 108(1): 12-20, Jan. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-838670

RESUMO

Abstract Background: Radionuclide ventriculography (RV) is a validated method to evaluate the left ventricular systolic function (LVSF) in small rodents. However, no prior study has compared the results of RV with those obtained by other imaging methods in this context. Objectives: To compare the results of LVSF obtained by RV and echocardiography (ECHO) in an experimental model of cardiotoxicity due to doxorubicin (DXR) in rats. Methods: Adult male Wistar rats serving as controls (n = 7) or receiving DXR (n = 22) in accumulated doses of 8, 12, and 16 mg/kg were evaluated with ECHO performed with a Sonos 5500 Philips equipment (12-MHz transducer) and RV obtained with an Orbiter-Siemens gamma camera using a pinhole collimator with a 4-mm aperture. Histopathological quantification of myocardial fibrosis was performed after euthanasia. Results: The control animals showed comparable results in the LVSF analysis obtained with ECHO and RV (83.5 ± 5% and 82.8 ± 2.8%, respectively, p > 0.05). The animals that received DXR presented lower LVSF values when compared with controls (p < 0.05); however, the LVSF values obtained by RV (60.6 ± 12.5%) were lower than those obtained by ECHO (71.8 ± 10.1%, p = 0.0004) in this group. An analysis of the correlation between the LVSF and myocardial fibrosis showed a moderate correlation when the LVSF was assessed by ECHO (r = -0.69, p = 0.0002) and a stronger correlation when it was assessed by RV (r = -0.79, p < 0.0001). On multiple regression analysis, only RV correlated independently with myocardial fibrosis. Conclusion: RV is an alternative method to assess the left ventricular function in small rodents in vivo. When compared with ECHO, RV showed a better correlation with the degree of myocardial injury in a model of DXR-induced cardiotoxicity.


Resumo Fundamento: A ventriculografia radioisotópica (VRI) é um método validado para avaliação da função sistólica do ventrículo esquerdo (FSVE) em pequenos roedores. Contudo, nenhum estudo prévio comparou os resultados obtidos com VRI com os obtidos por outros métodos de imagem neste contexto. Objetivos: Comparar os resultados de FSVE obtidos por VRI e por ecocardiografia (ECO) em modelo experimental de cardiotoxicidade por doxorrubicina (DXR) em ratos. Métodos: Ratos Wistar machos adultos controles (n = 7) e tratados com DXR (n = 22) em doses acumuladas de 8, 12 e 16 mg/kg, foram avaliados com ECO com equipamento Sonos 5500 Philips (transdutor de 12 MHz) e VRI adquirida em gama-câmara Orbiter-Siemens com colimador pinhole de 4 mm de abertura. Após eutanásia, foi realizada a quantificação histopatológica da fibrose miocárdica. Resultados: Os animais controles apresentaram valores comparáveis na análise da FSVE à ECO e à VRI (83,5 ± 5% e 82,8 ± 2,8%, respectivamente, p > 0,05). Os animais que receberam DXR apresentaram valores menores de FSVE quando comparados aos dos controles (p < 0,05); entretanto, observou-se neste grupo menores valores de FSVE obtidos por VRI (60,6 ± 12,5%) quando comparados aos obtidos pela ECO (71,8 ± 10,1%, p = 0,0004). A análise da correlação entre a FSVE e a fibrose miocárdica mostrou uma correlação moderada quando a FSVE foi estimada com a ECO (r = -0,69, p = 0,0002) e mais forte quando a FSVE foi obtida por VRI (r = -0,79, p < 0,0001). Apenas a VRI apresentou correlação de forma independente com a fibrose miocárdica à análise de regressão múltipla. Conclusão: A VRI é um método alternativo para avaliação da função ventricular esquerda in vivo em pequenos roedores, exibindo comparativamente à ECO melhor correlação com o grau de lesão miocárdica no modelo de cardiotoxicidade por DXR.


Assuntos
Animais , Masculino , Ecocardiografia , Ventriculografia com Radionuclídeos , Função Ventricular Esquerda/efeitos dos fármacos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Valores de Referência , Fibrose , Doxorrubicina , Reprodutibilidade dos Testes , Ratos Wistar , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/patologia , Estatísticas não Paramétricas , Modelos Animais de Doenças , Cardiotoxicidade/diagnóstico por imagem , Antibióticos Antineoplásicos
6.
Arq Bras Cardiol ; 101(1): 59-67, 2013 Jul.
Artigo em Inglês, Português | MEDLINE | ID: mdl-23917507

RESUMO

BACKGROUND: Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. OBJECTIVE: To determine the accuracy of this system for quantification of myocardial infarct area in rats. METHODS: Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq o f 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. RESULTS: The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. CONCLUSION: The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.


Assuntos
Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Precisão da Medição Dimensional , Processamento de Imagem Assistida por Computador , Masculino , Infarto do Miocárdio/patologia , Ratos , Ratos Wistar , Valores de Referência , Fatores de Tempo , Tomografia Computadorizada de Emissão de Fóton Único/economia , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
7.
Arq. bras. cardiol ; 101(1): 59-67, jul. 2013. ilus
Artigo em Português | LILACS | ID: lil-681836

RESUMO

FUNDAMENTO: Técnicas de imageamento in vivo permitem avaliar sequencialmente a morfologia e a função dos órgãos em diversos modelos experimentais. Desenvolvemos um dispositivo de adaptação de uma gama-câmara clínica para obter imagens tomográficas por emissão de fótons singulares (SPECT) de alta resolução, baseado em colimador pinhole. OBJETIVO: Determinar a acurácia desse sistema na quantificação da área de infarto miocárdico em ratos. MÉTODOS: Treze ratos Wistar machos (250 g) foram submetidos a infarto do miocárdio por oclusão da artéria coronária esquerda. Após 4 semanas, foram adquiridas imagens tomográficas com o sistema desenvolvido, 1,5 hora após a injeção endovenosa de 555MBq de 99mTc-Sestamibi. Na reconstrução tomográfica, utilizamos software especialmente desenvolvido baseado no algoritmo de Máxima Verossimilhança. Comparamos as médias e analisamos a correlação entre a extensão dos defeitos perfusionais detectados pela cintilografia e a extensão da fibrose miocárdica avaliada pela histologia. RESULTADOS: As imagens apresentaram ótima relação órgão-alvo/fundo, com apropriada visualização das paredes e da cavidade do ventrículo esquerdo. Todos os animais exibindo áreas de infarto foram corretamente identificados pelas imagens de perfusão. Não houve diferença entre a área do infarto medida pelo SPECT (21,1 ± 21,2%) e pela histologia (21,7 ± 22,0%; p = 0,45), obtendo forte correlação entre os valores da área de infarto mensurada pelos dois métodos (r = 0,99; p < 0,0001). CONCLUSÃO: O sistema desenvolvido apresentou resolução espacial adequada e elevada acurácia para detecção e quantificação das áreas de infarto miocárdico, sendo uma opção de baixo custo e grande versatilidade na obtenção de imagens em SPECT de alta resolução de órgãos de pequenos roedores.


BACKGROUND: Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. OBJECTIVE: To determine the accuracy of this system for quantification of myocardial infarct area in rats. METHODS: Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq o f 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. RESULTS: The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. CONCLUSION: The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.


Assuntos
Animais , Masculino , Ratos , Infarto do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Precisão da Medição Dimensional , Processamento de Imagem Assistida por Computador , Infarto do Miocárdio/patologia , Ratos Wistar , Valores de Referência , Fatores de Tempo , Tomografia Computadorizada de Emissão de Fóton Único/economia , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
8.
Arq. bras. cardiol ; 97(1): 59-64, jul. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-597659

RESUMO

FUNDAMENTO: A insuficiência cardíaca crônica (IC) é uma síndrome complexa caracterizada pela redução do débito cardíaco em relação às necessidades metabólicas do organismo, bem como alterações metabólicas e do eixo neuro-hormonal. Sintomas como fadiga muscular e dispneia são notórios e os testes de esforço são amplamente utilizados para a avaliação da capacidade funcional, prognóstico e eficácia das intervenções terapêuticas nessa síndrome. OBJETIVO: Avaliar a reprodutibilidade do teste de caminhada de seis minutos (TC6') em pacientes com IC e correlacionar a magnitude das variáveis atingidas no pico do esforço do TC6' com as de um teste cardiopulmonar (TCP). MÉTODOS: Foram estudados 16 pacientes (12 homens e 4 mulheres) com diagnóstico de IC CF I-II (NYHA). Os voluntários foram submetidos a dois testes TC6' (TC6'1 e TC6'2) com intervalo de 30 minutos entre eles; posteriormente realizaram um TCP máximo. RESULTADOS: Todas as variáveis obtidas nos dois TC6' mostraram-se significantes, com altas correlações: distância percorrida (DP) (r = 0,93; p < 0,0001), frequência cardíaca (FC) (r = 0,89; p < 0,0001), consumo de oxigênio (VO2) (r = 0,93; p < 0,0001) e escala de percepção de esforço (r = 0,85; p < 0,0001). Por sua vez, todas as variáveis analisadas no TC6' mostraram correlações moderadas e significantes com as variáveis obtidas no TCP, a saber: FC pico (r = 0,66; p = 0,005); VO2 (r = 0,57; p = 0,02) e VO2 no TCP e DP no TC6'2 (r = 0,70; p = 0,002). CONCLUSÃO: O TC6' foi reprodutível nesse grupo de pacientes com IC (NYHA - I-II) e se correlacionou com o TCP. Sendo assim, apresenta-se como ferramenta de avaliação fidedigna, constituindo-se numa alternativa adequada, segura e de baixo custo para a prescrição de exercícios físicos aeróbicos em pacientes com IC.


BACKGROUND: Chronic heart failure (HF) is a syndrome characterized by reduced cardiac output in relation to the metabolic needs of the organism, as well as metabolic and neurohormonal axis abnormalities. Symptoms such as fatigue and dyspnoea are notorious and stress tests are widely used to assess functional capacity, prognosis and effectiveness of therapeutic interventions in this syndrome. OBJECTIVE: To evaluate the reproducibility of the six-minute walk test (6MW) in patients with HF and correlate the magnitude of the variables reached at peak exercise of the 6MWT with a cardiopulmonary exercise test (CPET). METHODS: We studied 16 patients (12 men and 4 women) diagnosed with HF FC I-II (NYHA). The volunteers underwent two 6MWT (6MWT'1 and 6MWT'2) with 30-minute interval between them; then, they underwent a maximum CPET. RESULTS: All variables obtained in the two 6MWT' proved to be significant with high correlations: distance walked (DW) (r = 0.93, p < 0.0001), heart rate (HR) (r = 0.89, p < 0.0001), oxygen consumption (VO2) (r = 0.93, p < 0.0001) and scale of perceived exertion (r = 0.85, p < 0.0001). In turn, all variables analyzed in the 6MWT' showed significant and moderate correlations with the variables obtained from the CPET, namely: peak HR (r = 0.66; p = 0.005); VO2 (r = 0.57; p = 0.02) and VO2 in the CPET and DT in the 6MWT'2 (r = 0.70; p = 0.002). CONCLUSION: The 6MWT was reproducible in this group of patients with HF (NYHA - I-II) and correlated with the CPET. Therefore, it is a tool for reliable evaluation, and a suitable, safe and low-cost alternative for the prescription of aerobic exercise in patients with HF.


FUNDAMENTO: La insuficiencia cardíaca crónica (IC), es un síndrome complejo que se caracteriza por la reducción del débito cardíaco con relación a las necesidades metabólicas del organismo, como también por las alteraciones metabólicas y del eje neuro hormonal. Los síntomas como el cansancio muscular y la disnea son notables y los test de esfuerzo son ampliamente utilizados para la evaluación de la capacidad funcional, pronóstico y eficacia de las intervenciones terapéuticas en ese síndrome. OBJETIVO: Evaluar la reproductibilidad del test de esfuerzo de seis minutos (TE6') en pacientes con IC y correlacionar la magnitud de las variables alcanzadas en el pico del esfuerzo del TE6' con las de un test cardiopulmonar (TECP). MÉTODOS: Se estudiaron 16 pacientes (12 hombres y 4 mujeres) con un diagnóstico de IC CF I-II (NYHA). Los voluntarios se sometieron a dos test TE6' (TC6'1 y TC6'2), con un intervalo de 30 minutos entre ellos. Posteriormente realizaron un TECP máximo. RESULTADOS: Todas las variables obtenidas en los dos TE6' fueron significativas, y con altas correlaciones: distancia recorrida (DR) (r = 0,93; p < 0,0001), frecuencia cardíaca (FC) (r = 0,89; p < 0,0001), consumo de oxígeno (VO2) (r = 0,93; p < 0,0001) y escala de percepción de esfuerzo (r = 0,85; p < 0,0001). A su vez, todas las variables analizadas en el TE6' mostraron correlaciones moderadas y significativas con las variables obtenidas en el TECP, a saber: FC pico (r = 0,66; p = 0,005); VO2 (r = 0,57; p = 0,02) y VO2 en el TECP y DR en el TE6'2 (r = 0,70; p = 0,002). CONCLUSIÓN: El TE6' se pudo reproducir en ese grupo de pacientes con IC (NYHA - I-II) y se correlacionó con el TECP. Por lo tanto, se presenta como una herramienta de evaluación fidedigna y constituye una alternativa adecuada, segura y de bajo coste para la prescripción de ejercicios físicos aeróbicos en pacientes con IC.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Teste de Esforço , Insuficiência Cardíaca/fisiopatologia , Tolerância ao Exercício/fisiologia , Consumo de Oxigênio/fisiologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Testes de Função Respiratória , Estatísticas não Paramétricas , Fatores de Tempo , Caminhada/fisiologia
9.
Arq Bras Cardiol ; 97(1): 59-64, 2011 Jul.
Artigo em Inglês, Português, Espanhol | MEDLINE | ID: mdl-21552646

RESUMO

BACKGROUND: Chronic heart failure (HF) is a syndrome characterized by reduced cardiac output in relation to the metabolic needs of the organism, as well as metabolic and neurohormonal axis abnormalities. Symptoms such as fatigue and dyspnoea are notorious and stress tests are widely used to assess functional capacity, prognosis and effectiveness of therapeutic interventions in this syndrome. OBJECTIVE: To evaluate the reproducibility of the six-minute walk test (6MW) in patients with HF and correlate the magnitude of the variables reached at peak exercise of the 6MWT with a cardiopulmonary exercise test (CPET). METHODS: We studied 16 patients (12 men and 4 women) diagnosed with HF FC I-II (NYHA). The volunteers underwent two 6MWT (6MWT'1 and 6MWT'2) with 30-minute interval between them; then, they underwent a maximum CPET. RESULTS: All variables obtained in the two 6MWT' proved to be significant with high correlations: distance walked (DW) (r = 0.93, p < 0.0001), heart rate (HR) (r = 0.89, p < 0.0001), oxygen consumption (VO2) (r = 0.93, p < 0.0001) and scale of perceived exertion (r = 0.85, p < 0.0001). In turn, all variables analyzed in the 6MWT' showed significant and moderate correlations with the variables obtained from the CPET, namely: peak HR (r = 0.66; p = 0.005); VO2 (r = 0.57; p = 0.02) and VO2 in the CPET and DT in the 6MWT'2 (r = 0.70; p = 0.002). CONCLUSION: The 6MWT was reproducible in this group of patients with HF (NYHA - I-II) and correlated with the CPET. Therefore, it is a tool for reliable evaluation, and a suitable, safe and low-cost alternative for the prescription of aerobic exercise in patients with HF.


Assuntos
Teste de Esforço , Insuficiência Cardíaca/fisiopatologia , Idoso , Tolerância ao Exercício/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Testes de Função Respiratória , Estatísticas não Paramétricas , Fatores de Tempo , Caminhada/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...